Manual S Equipment Selection in City of the Sun, NM for $100.
Manual S equipment selection for City of the Sun, NM: we check your heat pump, AC or furnace against the Manual J loads using manufacturer performance data. $100 with Manual J and D included.
- J + S + D for $100
- Permit-ready PDF
- 2–3 business days
- No subscription

Free quote confirmation, no account needed. You pay per house, no subscription.
Load calculations for City of the Sun.
City of the Sun is in IECC climate zone 3B (warm, dry).
Mostly cooling with a real heating season. Heat pumps fit well when both loads are calculated. Dry air: the cooling load is mostly sensible, so equipment with a high sensible ratio fits.
Climate zone by county (Luna County) per the DOE / IECC county assignment. Your jurisdiction’s adopted code edition decides; we use the local design temperatures for the project address.
- County
- Luna County
- IECC climate zone
- 3B
- Area
- 0.3 sq mi
For projects in City of the Sun you do not need a local office: send the plans by email and receive the Manual J, S or D as a PDF.
Population: US Census Bureau estimates. City of the Sun is a community in Luna County, New Mexico.
J, S & D for $100 in City of the Sun. All three.
One price for every builder and every contractor, from the first house. No subscription, no software license, no minimum order.
Manual J + S + D
All three reports for one house, matched to each other, in one PDF package.
Order for $100Manual J
Room-by-room heating and cooling loads (sensible and latent) to ACCA Manual J 8th Edition.
Manual S
Checks the furnace, heat pump or AC you plan against the Manual J loads and manufacturer data.
Manual D
Duct sizing per room: airflow (CFM), supply and return sizes, friction rate and static pressure.
$100 per dwelling unit for all three reports, also if you need only one of them. Confirmed before we start. Unusual projects (very large custom homes, more than two systems) are quoted first.
A report your plan reviewer recognizes.
Every report is built from your actual plans and the design conditions for City of the Sun, and delivered as one PDF you can upload with the permit application.
Example screen with sample numbers (heating / cooling Btu/h per room). Your report uses your plans.
Square feet per ton is not a calculation.
Two houses with the same floor area can need very different equipment. Windows, orientation, insulation, air leakage, duct location and climate change the load. Codes require ACCA Manual J and Manual S because rules of thumb usually oversize.
For builders and HVAC contractors in City of the Sun.
We work as your back office for load calculations: you build and install, we deliver the numbers and the paperwork.

Home builders & developers
- Manual J, S and D with every permit set
- Same $100 price for one house or a whole subdivision
- Repeat plans: we keep your models on file
- One contact for all your projects

HVAC contractors
- Size equipment right and win the bid on facts
- Load calc for replacement permits and rebates
- Manual D before the duct crew starts
- No software license, pay only when you have a job
Manual J in City of the Sun in three steps.
- Send your plansAnswer four questions, then email or upload floor plans, elevations, window schedule and insulation specs.
- We calculateManual J loads, Manual S equipment check and Manual D duct design, matched to each other.
- Permit-ready PDFDelivered in 2–3 business days. If plan review asks for changes to our report, we revise it free.



Send the plan set. We do the rest.
- Floor plans of every level with dimensions
- Elevations or the direction the front door faces
- Window and door schedule (sizes, U-factor, SHGC)
- Insulation levels: walls, ceiling/attic, floor, slab or basement
- Ceiling heights and any vaulted areas
- Duct location (attic, crawlspace, conditioned space)
- Planned equipment type: heat pump, AC + furnace, mini-split
- Air leakage target if known (ACH50)
Missing something? We tell you before we start and use code minimums only if you confirm.

Manual S Equipment Selection in City of the Sun, answered.
What does Manual S check?
Whether the equipment you plan delivers enough heating, sensible and latent cooling at local design conditions without being oversized beyond the Manual S limits, using the manufacturer’s expanded performance data.
Do you need to visit the site in City of the Sun?
No. We work from your plans and specifications, so a project in City of the Sun is handled remotely like any other. If a detail is missing, we ask before we start.
What climate zone is City of the Sun in?
City of the Sun is in Luna County, which is assigned to IECC climate zone 3B. Your local building department’s adopted code edition is what counts, and we use the design temperatures for the project location.
How much does a Manual J cost?
$100 per house for Manual J, Manual S and Manual D together. No subscription and no minimum order.
How fast do I get the report?
Usually 2–3 business days after we receive complete plans and specs.
Will the building department accept it?
Reports follow ACCA Manual J 8th Edition, Manual S and Manual D and use the plans you send. Acceptance is up to your building department; if plan review asks for corrections to our report, we revise it at no charge.
Do you work with builders and contractors on many houses?
Yes. Builders and HVAC contractors are our main customers. The price stays $100 per house for J, S and D, and repeat plans are kept on file.

Your next permit, sized right.
Manual J, S and D together for $100 in City of the Sun. Send the plans today.
Order nowOther services in City of the Sun.
- Manual J Calculation in City of the Sun
- Manual J Load Calculation in City of the Sun
- HVAC Load Calculation in City of the Sun
- Air Conditioning Load Calculation in City of the Sun
- Manual J, S & D in City of the Sun
- Manual D Duct Design in City of the Sun
- Heat Load Calculation in City of the Sun
- Manual J Calculation Service in City of the Sun
- HVAC Sizing Calculation in City of the Sun