Duct layout · ASHRAE 62.2 · AHRI · REScheck · ENERGY STAR

Every HVAC document your permit may ask for.

What a duct layout drawing, an ASHRAE 62.2 ventilation calculation, an AHRI certificate, a REScheck report and the ENERGY STAR HVAC Design Report are, and when you need them. All included in Loadpol Unlimited, $250 a month.

Start Unlimited · $250/mo Try it free – first house on us

Your first house is free: create an account and upload one project – no agreement, no credit card.

  • First house free
  • Unlimited houses
  • J + S + D done for you
  • 2–3 business days
  • Plans or LiDAR scan

Example screen with sample numbers (heating / cooling Btu/h per room). Your report uses your plans.

  • ACCA-approved software
  • Wrightsoft Right-J8 & Right-D
  • Manual J 8th Ed. · S · D
  • Permit-ready PDF
  • Plans or LiDAR scan
  • All 50 states

Wrightsoft Right-J8 and Right-D are on ACCA’s approved software list. Loadpol is not affiliated with or endorsed by ACCA or Wrightsoft.

Questions first?

Not ready to sign up? Ask us.

Four quick questions about your projects. We reply within one business day.

Loadpol Unlimited · $250/month

For builders, developers and HVAC contractors. Unlimited houses with Manual J, S and D for $250 a month, 12-month agreement.

Manual J, S and D: the core set

Manual J calculates the heating and cooling loads room by room, Manual S checks the planned equipment against those loads with manufacturer data, and Manual D sizes the ducts for the airflow each room needs. Building codes based on the IRC and IECC reference all three. They are the basis for every other document on this page.

HVAC duct layout drawing

A plan sheet drawn over the floor plan that shows the duct runs, the supply outlets and registers per room, the return grilles and return path, and where the furnace, air handler or heat pump sits. Many plan reviewers want to see where the ducts run and that the sizes match the Manual D, and install crews build from it. We draw it from the Manual D design in Wrightsoft Right-Draw / Right-D and deliver it as a PDF.

ASHRAE 62.2 whole-house ventilation

ASHRAE Standard 62.2 sets the minimum mechanical ventilation for homes. In the 2016 and 2019 editions the whole-house rate is Qtot = 0.03 × conditioned floor area (sq ft) + 7.5 × (number of bedrooms + 1), in cfm. Example by the formula: a 2,000 sq ft house with 3 bedrooms needs 0.03 × 2,000 + 7.5 × 4 = 90 cfm. A credit for natural infiltration may reduce the mechanical rate, but only when a measured blower-door result is available – we apply it only if you send one. You need it when your jurisdiction or a program (for example ENERGY STAR) asks for ASHRAE 62.2; codes based on the IRC have their own ventilation table, and we state in the report which method we used. It appears as its own section in the report.

AHRI Directory certificate

The AHRI Directory of Certified Product Performance is a public database of certified equipment combinations. Its certificate shows a matched system – the outdoor unit with a specific indoor coil or air handler (and furnace, where it applies) – with its certified ratings. Rebate and tax-credit programs, utilities and some plan reviewers ask for it to prove that the installed combination is a certified match. We look up the combination that fits the Manual S selection in the brand or model line you name (otherwise a suitable combination from the requested line) and attach the certificate as a PDF: an AHRI Directory certificate from the public lookup.

REScheck compliance report

REScheck is the free software of the U.S. Department of Energy for showing that a new home or addition meets the residential energy code (IECC or a state code based on it), usually through the envelope trade-off. Many building departments accept a REScheck report with the permit. We prepare it from the Manual J data. The compliance report is signed by the builder or designer of record, and the building department decides whether it accepts REScheck. Not available in Florida (own energy code compliance method, Form R405 with approved software) and California (Title 24).

ENERGY STAR HVAC Design Report

Homes built to the ENERGY STAR Single-Family New Homes program need an HVAC Design Report: design conditions, Manual J loads, the Manual S equipment selection, the Manual D duct design and the ventilation design, on the program form. The HVAC designer completes it and the rater checks it against the house. We complete the HVAC Design Report from our Manual J, S and D results on the current form version; the HVAC designer of record and rater requirements of the program apply. It is not a certification of the home.

Rush 24h

When a permit or an inspection cannot wait, tick Rush in the project: we deliver within 24 hours on business days after we confirm your documents are complete. It costs $49 per house, billed with your next monthly invoice – and if we miss the deadline, the Rush fee is dropped. Everything else on this page is included in Loadpol Unlimited at no extra cost.

Last reviewed November 2026. Code sections refer to the International Residential Code and International Energy Conservation Code; local amendments may apply.

Pricing

Unlimited Manual J, S & D. $250 a month.

One plan for builders, developers and HVAC contractors: upload every house you permit, our team calculates them all.

One plan · everything included

Loadpol Unlimited

$250 / month

Unlimited houses with Manual J, S and D plus duct layout drawing, ASHRAE 62.2 ventilation, AHRI certificate, REScheck and ENERGY STAR HVAC Design Report. No per-house fees.

Start Unlimited

Try it free – your first house is on us, no credit card. Create an account.

12-month agreement signed online, then month to month with 30 days’ notice. Billed monthly by Stage Strategy USA, Inc.

What’s included
  • Unlimited houses every month – no per-house fee
  • Manual J room-by-room heating and cooling loads
  • Manual S equipment selection with manufacturer data
  • Manual D duct design: airflow, sizes, static pressure
  • HVAC duct layout drawing (ducts, registers, returns, equipment)
  • ASHRAE 62.2 whole-house ventilation rate
  • AHRI Directory certificate for the matched system
  • REScheck compliance report (not available in FL and CA)
  • ENERGY STAR HVAC Design Report, filled in from J, S and D
  • Calculated by our team in ACCA-approved software
  • Permit-ready PDFs, typically 2–3 business days after complete plans
  • Plans or a LiDAR scan of an existing house
  • Free revisions when plan review asks for changes
  • Your plans and models kept on file for repeat lots
  • Your logo and company details on every report
  • Built-in CRM: customers, proposals with energy-savings chart, invoices
  • Read-only share links for HERS raters and building departments
  • Export to ServiceTitan / Housecall Pro (CSV) and open API
Optional: Rush 24h

Documents within 24 hours on business days after we confirm your documents are complete. If we miss it, there is no fee. Billed with your next monthly invoice.

+$49 / house

No single orders. A house is one building with one floor plan at one address; REScheck not available in FL and CA. Details in the Terms.

What you get

A report your plan reviewer recognizes.

Every report is built from your actual plans, and delivered as one PDF you can upload with the permit application.

Room by roomHeating, sensible and latent cooling load and airflow for every room.
Code referencesPrepared to ACCA Manual J 8th Edition, Manual S and Manual D in ACCA-approved software.
Matched equipmentManual S check against manufacturer data for the unit you plan.
Duct sizesManual D supply and return sizes, friction rate and static pressure.
House plans used for a room-by-room load calculation
FAQ

HVAC Permit Documents Explained: answered.

Do all these documents cost extra?

No. Manual J, S and D, the duct layout drawing, ASHRAE 62.2 ventilation, the AHRI certificate, REScheck and the ENERGY STAR HVAC Design Report are all included in Loadpol Unlimited at $250 a month. Only Rush 24h is an option at $49 per house.

Why no REScheck in Florida and California?

Both states use their own energy code compliance methods: Florida the Florida Building Code, Energy Conservation, with approved software (Form R405), California Title 24. REScheck does not apply there.

Do you use the AHRI or ENERGY STAR logos?

No. We attach the public AHRI Directory certificate and fill in the ENERGY STAR program form. Loadpol is not affiliated with AHRI, the U.S. DOE or ENERGY STAR.

How much does a Manual J cost?

Loadpol Unlimited is $250 a month for unlimited houses, each with Manual J, Manual S and Manual D, calculated by our team. 12-month agreement, then month to month. No per-house fees.

What documents are included?

Everything the building department needs for the HVAC side, for every house: Manual J, Manual S, Manual D, an HVAC duct layout drawing, the ASHRAE 62.2 whole-house ventilation rate, an AHRI Directory certificate (public lookup) for the matched system, a REScheck compliance report for new homes and additions where REScheck is accepted (not available in FL and CA) and the ENERGY STAR HVAC Design Report filled in from our Manual J, S and D. All included in the $250 a month, plus free plan-review revisions.

Is there a rush option?

Yes: Rush 24h for $49 per house. We deliver within 24 hours on business days after we confirm your documents are complete. If we miss the deadline, the Rush fee is dropped. It is billed with your next monthly invoice; available with Loadpol Unlimited, not for the free trial house.

Start Unlimited · $250/mo →