Sample report

See a real Manual J, S & D.

Calculated in ACCA-approved Wrightsoft Right-Suite Universal by the Loadpol team – for a fictional 2,160 sq ft, two-story home in Austin, TX.

Try it free Download the PDF

  • Real Wrightsoft report
  • Fictional house
  • Not for permit use
Sample report video: room loads, duct design and report pages of the sample house
Product video · numbers from our sample report (real Wrightsoft calculation, fictional house) and the demo CRM proposal.
  • $250a month, unlimited houses
  • 2–3business days, typical
  • 8permit documents included
  • 50states · 31,993 places
  • 1sthouse free to try

Calculated in ACCA-approved software (Wrightsoft Right-J8 and Right-D are on ACCA’s approved software list). Loadpol is not affiliated with ACCA or Wrightsoft.

Sample Home at a glance

2,160 sq ft · 2 stories · 3 bedrooms.

Austin, Bergstrom IAP, TX (ACCA design conditions): 30 °F / 98 °F.

  • 29,496Btu/h heating
  • 23,889Btu/h cooling
  • 2.5 tonheat pump
  • 0.068in./100 ft friction
  • 52 cfmventilation (ERV)
First floor · 1,080 sq ftLiving Room300 sq ft4,514 / 2,662Kitchen-Dining300 sq ft4,514 / 4,375Study144 sq ft2,975 / 1,525Foyer-Stairs192 sq ft2,306 / 1,034Laundry144 sq ft3,260 / 1,350
Second floor · 1,080 sq ftMaster Bedroom240 sq ft2,596 / 2,286Master Bath192 sq ft2,128 / 1,504Bedroom 2156 sq ft1,044 / 808Upstairs Hall168 sq ft1,055 / 839Bedroom 3156 sq ft2,012 / 1,718Bath 2168 sq ft1,975 / 1,392

Heating / sensible cooling in Btu/h per room, from the Right-J worksheets. Schematic plans.

Download

The full Wrightsoft report, 12 pages.

Every page is stamped “SAMPLE – for illustration only, not for permit use”.

Download the sample report (PDF)

Loadpol cover sheet – sample

Loadpol cover sheet

Key results of the report on one page.

Download PDF
Ventilation sheet – sample

Ventilation sheet

ASHRAE 62.2-2010 / IRC: 52 cfm via ERV.

Download PDF
Manual S · load vs capacityTotal cooling111%Sensible107%Latent130%Heating at 30 °F+5 kWGrey = load · green = heat pump at design conditions · amber = 5 kW backup
Manual S

2.5-ton heat pump, 111% of the cooling load.

  • Goodman GLZS4BA3010A heat pump + AMVT42CP1300A air handler
  • AHRI ref. 215884104 · SEER2 15.2 · HSPF2 7.8
  • Balance point 33 °F, 5 kW backup heat
Also in a real project

Official forms, attached as issued.

AHRI certificateThe public AHRI Directory certificate for your matched system.
REScheckThe DOE compliance report for your house (not FL / CA).
ENERGY STAR HVAC Design ReportThe program form, filled in from your J, S and D.
Pricing

One price: $250 a month.

For builders, developers and HVAC contractors.

One plan · everything included

Loadpol Unlimited

$250/month

Unlimited houses. Done for you.

Try it free

First house free – no agreement, no card. Then 12-month agreement from the day you sign, month to month after.

  • Unlimited houses, no per-house fee
  • Manual J, S and D
  • Duct layout drawing
  • ASHRAE 62.2 ventilation
  • AHRI certificate
  • REScheck (not FL / CA)
  • ENERGY STAR HVAC Design Report
  • Free plan-review revisions
  • Your logo on every report
  • Built-in CRM

Full details →

FAQ

Sample report: questions.

More questions? info@loadpol.com

Is the sample a real house?

No. The house and its address are fictional. The calculation is real: our team entered it in Wrightsoft Right-Suite Universal like any customer project. Every page is stamped SAMPLE – not for permit use.

Does my report look like this?

Yes. Your permit reports come from the same software (Wrightsoft Right-Suite Universal, on ACCA’s approved software list) with the same pages, for your plans and your address.

Why are AHRI, REScheck and ENERGY STAR not in the sample?

Those are official certificates and forms. We attach them for your project as issued; we do not reproduce them for a fictional house.

How much does a Manual J cost?

Loadpol Unlimited is $250 a month for unlimited houses, each with Manual J, Manual S and Manual D, calculated by our team. 12-month agreement that starts on the day you sign (first invoice right away), then month to month. No per-house fees.

What documents are included?

Everything the building department needs for the HVAC side, for every house: Manual J, Manual S, Manual D, an HVAC duct layout drawing, the ASHRAE 62.2 whole-house ventilation rate, an AHRI Directory certificate (public lookup) for the matched system, a REScheck compliance report for new homes and additions where REScheck is accepted (not available in FL and CA) and the ENERGY STAR HVAC Design Report filled in from our Manual J, S and D. All included in the $250 a month, plus free plan-review revisions. There are no extras.

Your next permit, sized right.

Unlimited Manual J, S and D for $250 a month. First house free.

Try it free Sample report

Try it free – first house on us →